Search results for "Photorefractive keratectomy"
showing 10 items of 17 documents
Changes in Tear Protein Pattern after Photorefractive Keratectomy
2003
PURPOSE. Changes in tear protein composition of patients who underwent photorefractive keratectomy (PRK) were analyzed. METHODS. Tear samples were obtained from 23 eyes of 23 patients immediately before PRK and on the fourth postoperative day with glass capillaries. Tear proteins were separated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Digital image analysis and evaluation of the densitometric data of the electrophoretic separations were done with BioDoc-Analyze. RESULTS. Analysis of discriminance found a significant difference in the protein patterns (p<0.001). This type of analysis of the electrophoretic densitographs uses all peak information simultaneously. A signifi…
Intraocular pressure after excimer laser myopic refractive surgery
2001
The aim of this study was to determine whether intraocular pressure (IOP), as measured by Goldmann applanation or non-contact tonometry, shows systematic changes in patients who have undergone photorefractive keratectomy (PRK) or laser in situ keratomileusis (LASIK). IOP was measured by central Goldmann and non-contact tonometry in 54 patients pre and post-PRK, and in 43 patients pre- and post-LASIK. An interval of 12 months was allowed after surgery. Patients were selected to have one of four specific initial values of refractive error (-2.5, -5.0, -7.5 and -10.0 D). Fellow unoperated eyes were used as controls. A paired Student's t-test and a one-way ANOVA test were used for statistical a…
Image quality and visual performance in the peripheral visual field following photorefractive keratectomy.
2002
ABSTRACT PURPOSE: A theoretical and experimental study was performed to assess the possible effects of photorefractive keratectomy (PRK) on retinal image quality and thresholds in the peripheral visual field. METHODS: Simple optical calculations suggest that although the quality of the retinal image at the fovea of the postoperative PRK eye may be comparable to that in an emmetropic eye, images in the peripheral field may be markedly worse, since peripheral ray bundles may pass partly through ablated and partly through unablated cornea, giving a simultaneous-vision bifocal effect. This would be expected to create an annular zone of confusion, so that light from two different directions in o…
Influence of Refraction on Tonometric Readings After Photorefractive Keratectomy and Laser Assisted In Situ Keratomileusis
2000
PURPOSE To determine the decrease of Goldmann tonometry after photorefractive keratectomy (PRK) and laser assisted in situ keratomileusis (LASIK) according to refraction prior to surgery. METHODS Prospective simultaneous comparative case series of 53 myopic eyes (53 patients) that underwent PRK and 50 (50 patients) that underwent LASIK using the Summit Excimed SVS plus (Summit Technology, Inc., Walthan, MA, U.S.A.). PRK and LASIK were subdivided by refractive error into two subgroups of more than or less than -5 diopters (D). Central tonometric readings were taken prior to surgery and 12 months after surgery. RESULTS In LASIK and PRK subgroups of more than -5 D, 85.7% (24) and 69.6% (24), r…
Reproducibility of digital image analysis for measuring corneal haze after myopic photorefractive keratectomy.
1997
Purpose To evaluate the usefulness of digital image analysis for quantifying corneal haze by determining the reproducibility of its measurements at the corneal plane. Methods In a prospective study, 20 randomly selected eyes that had undergone myopic photorefractive keratectomy were photographed focusing the slit beam on their anterior corneal surface. Each photograph was examined using computer image analysis techniques that detect the edge of the reticular pattern of the image. Quantification of the difference between two areas, treated and adjacent untreated cornea, each containing 3,750 pixels with a resolution of 256 gray levels, was performed. Intra-analyzer variation was determined b…
Direct Objective Quantification of Corneal Haze after Excimer Laser Photorefractive Keratectomy for High Myopia
1996
Purpose: The purpose of the study is to measure regional distribution differences in corneal haze after excimer laser photorefractive keratectomy for high myopia. Methods: The authors developed computerized gradient edge detectors with which were analyzed digitized anterior slit-lamp photographs of 40 eyes, an average of 21.0 plus or minus 14.5 weeks after photorefractive keratectomy for high myopia (−6 to −22 diopters). A treated area and an adjacent untreated area on the anterior corneal surface, each containing six regions, were quantified, and the difference was correlated with various parameters. Results: Mean differences between scarred and clear areas for haze grade 0.5, 1.0, 2.0, 3.…
Mesopic contrast sensitivity function after excimer laser photorefractive keratectomy.
2002
ABSTRACT PURPOSE: To evaluate contrast sensitivity under mesopic conditions in patients who had undergone uncomplicated excimer laser photorefractive keratectomy (PRK) for myopia. METHODS: Monocular contrast sensitivity function was measured with the Stereo Optical ?A.C.T. chart in 26 patients who had received PRK using the Nidek EC-5000 excimer laser system. Mean preoperative refractive error was -6.23 ? 1.69 D (range, -4.00 to -8.25 D); postoperatively, mean refractive error was -0.36 ? 0.58 D (range, -0.75 to +0.50 D). Contrast sensitivity function was measured 6 months after surgery using four different chart luminances: 85, 5.0, 2.5, and 0.1 cd/m2, the first being a photopic level and …
Excimer laser photorefractive keratectomy for high myopia
1995
Abstract One hundred and thirty-three eyes of 103 patients had photorefractive keratectomy with a slit scan mode excimer laser for myopia ranging from −6.00 to −22.00 diopters (D). The epithelium was removed with 20% ethanol, and the ablation was done with a tapered profile surrounding the optical zone. Patients were divided into two groups based on preoperative myopia: Group A, −6.00 D to −12.00 D (88 eyes); Group B, −12.50 D to −22.00 D (45 eyes). In Group A, mean preoperative refraction was −9.59 ± 1.79 D. Mean postoperative refraction was −0.29 ± 1.47 D at one month, −0.85 ± 1.68 D at three months, −1.17 ± 2.04 D at six months, and −0.56 ± 0.74 D at one year. Anterior stromal haze was g…
Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism.
2013
PURPOSE: To compare visual and refractive results of Toric Implantable Collamer Lens (TICL) and bioptics (ICL plus excimer corneal surgery) to treat myopic astigmatism. METHODS: Eighty-one eyes underwent TICL implantation and 83 eyes were treated with bioptics (corneal ablation was performed between 1.5 and 6 months after ICL implantation). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, adverse events, safety, and efficacy were evaluated 12 months postoperatively. RESULTS: At 12 months postoperatively, the mean spherical equivalent was -0.15 ± 0.36 diopters (D) in the TICL group and -0.08 ± 0.26 D in the bioptics group (p = 0.099). Sixty-six …
Changes in the visual field following laser in situ keratomileusis for myopia
2007
Purpose: To assess the changes of the visual field (VF) caused by transient intraocular pressure (IOP) peaks during laser in situ keratomileusis (LASIK) surgery for myopia using automated perimetry. Methods: This prospective study involved 94 eyes of 94 patients who underwent a conventional LASIK procedure. A complete eye examination was carried out in which the IOP measurement, and Humphrey 24-2 SITA standard VF were tested prior to LASIK and 6 and 12 months after LASIK. Patients were divided into two subgroups according to their refractive error. VF global indices, Glaucoma Hemifield Test and the number of depressed points deviating at p < 5%, p < 2%, p < 1% and p < 0.5% on the Pattern …